AGFA CORP -- CR-166B COPYRAPID OFFSET DEVELOPER -- 6750-00N079651
=====================  Product Identification  =====================

Product ID:CR-166B COPYRAPID OFFSET DEVELOPER
MSDS Date:04/01/1991
FSC:6750
NIIN:00N079651
=== Responsible Party ===
Company Name:AGFA CORP
Address:100 CHALLENGER ROAD
City:RIDGEFIELD PARK
State:NJ
ZIP:07660
Country:US
Info Phone Num:201-440-2500;212-971-0260
Emergency Phone Num:303-623-5716;800-424-9300(CHEMTREC)
CAGE:HO790
=== Contractor Identification ===
Company Name:AGFA CORP
Address:100 CHALLENGER ROAD
Box:City:RIDGEFIELD PARK
State:NJ
ZIP:07660
Country:US
Phone:201-440-2500;303-623-5716
CAGE:HO790
Company Name:AGFA DIVISION/BAYER CORPORATION
Address:100 CHALLENGER ROAD
Box:City:RIDGEFIELD PARK
State:NJ
ZIP:07660
Country:US
Phone:210-440-2500
CAGE:59710

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM HYDROXIDE (CERCLA)
CAS:1310-73-2
RTECS #:WB4900000
Fraction by Wt: 1-5%
OSHA PEL:2 MG/M3
ACGIH TLV:C 2 MG/M3; 9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:HYDROQUINONE (SARA 302/313) (CERCLA). LD50 (ORAL, RAT):320
    MG/KG
CAS:123-31-9
RTECS #:MX3500000
Fraction by Wt: 1-5%
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3; 9495
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:4-METHYL-1-PHENYL-3-PYRAZOLIDONE; (METHYLPHENIDONE)
CAS:2654-57-1
Fraction by Wt: 0-1%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SODIUM SULFITE
CAS:7757-83-7
RTECS #:WE2150000
Fraction by Wt: 10-15%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:OF PERMITTING AUTHORITY & MAY REQUIRE PRETREATMENT.
RTECS #:9999999ZZ

Ingred Name:EYE PROT: AND FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE ING 2.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE CONTACT:MAY CAUSE SEVERE
    IRRIT & BURNING. SKIN CONTACT:MAY CAUSE SEVERE IRRIT & BURNS; MAY
    CAUSE ALLERGIC SKIN REACTION. INHAL:NORMALLY NO PROBLEM, BUT INHAL
    OF MIST COULD CAUSE RESP IRRITA TION. INGESTION:MAY CAUSE SEVERE
    IRRITATION OR BURNING OF THE MUCOUS MEMBRANES OR DIGESTIVE TRACT.
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CHRONIC:(NOTE: PERTAINS TO EACH
    INGREDIENT LISTED IN SECTION 2 PER 29 CFR SECT. 1910.1200) ING
    2:RPTD CNTCT CAN CAUSE SKIN SENSIT & ALLERGIC DERM. CHRONIC OVEREXP
    CAN CAUSE ANEMIA & DISCOLORA TION & CORNEAL OPACITY OF THE EYES.
    ING3:CNTCT W/SKIN MAY CAUSE SKIN IRRIT. LAB TEST INDICATED THE MATL
    IS A (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF RUNNING WATER FOR AT
    LEAST 15 MIN. OBTAIN MEDICAL ATTENTION. SKIN:FLUSH AFFECTED AREA
    PROMPTLY WITH WATER FOR 15 MINUTES. REMOVE CONTAMINATED CLOTHING.
    IN CASE OF	CONTINUED IRRITATION CONSULT PHYSICIAN. INHALATION:FOR
    OVEREXPOSURE, REMOVE TO FRESH AIR. INGEST:OBTAIN IMMEDIATE MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
    EVACUATE PERSONNEL TO SAFE AREA. KEEP PERSONNEL REMOVED AND UPWIND
    OF FIRE.
Unusual Fire/Explosion Hazard:NON-COMBUSTIBLE. WHEN HEATED TO DECOMP
    EMISSION OF TOXIC FUMES OF SO*2 IS POSSIBLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:NOTE:REVIEW SECTION IV AND SECTION VIII BEFORE
    PROECEEDING WITH CLEAN UP. USE APPROP PERSONAL PROT EQUIP DURING
    CLEAN UP. DIKE SPILL. PVNT LIQ FROM ENTERING SEWERS, WATERWAYS/LOW
    AREAS. SOAK UP W/SAND , OIL DRY/OTHER ABSORB MATL. (SUPDAT)
Neutralizing Agent:POWDERED CITRIC ACID.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN WELL VENTILATED AREA. KEEP
    CONTAINERS TIGHTLY CLOSED. DO NOT STORE WITH INCOMPATIBLE MATERIALS
    (SEE SECTION VI).
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
    AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES AND NORMAL
    ROOM VENTILATION. NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
    UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS (ING 6)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . APRONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:SAME AS WATER. VAP DENS:SAME AS WATER. EFTS OF OVEREXP:SKIN
    SENSITIZER. ALL OTHER INGREDIENTS IN SECTION II:A COMPUTERIZED
    LITERATURE SEARCH OF NATIONAL DATABASES DID NOT YIELD ANY CHRONIC
    EFTS ASS OC W/THESE MATERIALS. SPILL PROC:SPILL MAY BE NEUTRALIZED
    W/POWDERED CITRIC ACID. WASTE DISP METHOD:APPROVAL (ING 5)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SUPDAT
Vapor Density:SUPDAT
Spec Gravity:1.142 (H*2O=1)
pH:>13
Evaporation Rate & Reference:SAME AS WATER
Solubility in Water:100%
Appearance and Odor:CLEAR AND LIGHT YELLOW LIQUID. NO ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:NO
STRONG ACIDS, OXIDERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF SULFUR, CO*2. CARBON
    MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RECOVER NONUSABLE FREE LIQ AND/OR CONTAMD H*2O,
    & DISPOSE OF IN AN APPRVD & PERMITTED TREATMENT SYS. REMOVE
    NONUSABLE SOLID MATL AND/OR CONTAMD SOIL, FOR DISPOSAL IN APPRVD &
    PERMITTED LANDFILL. DISCH ARGE TO SEWER REQUIRES (SUPDAT)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,